We use cookies to provide you with a top-notch browsing experience. You can find more information about cookies here. By selecting "Accept Cookies" you accept their placement.

Learn more

LVM30A..
Lovato Electric level control with time delay for swimming pools and fountains

Product Inquiry

Product Inquiry

Lovato Electric level control with time delay for swimming pools and fountains

    DETAILED DESCRIPTION

    LVM30A..

    The Lovato Electric level control relay for conductive liquids, which provides the tank emptying or filling control, by rotating the MODE selector, by means of MIN and MAX (or only one) level electrodes. With the “Sensitivity” potentiometer, the adjustment of the relay sensitivity, between 2.5 and 50kΩ, is obtained.
    Using the “Delay” potentiometer, one of the two time delays can be obtained:
    PROBE delay: Mainly suitable for two- electrode operation to exclude the wave effect caused by liquid motion.
    START delay: Consents to delay the relay energising when the liquid level has reached the pump-starting threshold.
    The combination of LVM30A.. with the 11SN1 electrodes is a good solution for controlling of the swimming pools water level but you can use the VH3 and VH4 Carlo Gavazzi probes for more delicacy and durability (VH3 and VH4 are the ideal solution for high resistive in chlorine and sanitary).

    Level controller specification

    • Power supply: 24 V and 220-240 V AC or 110-127 V and 380-415 V AC
    • Sensitivity adjustment: 2.5 to 50 Κhm
    • Functions: for filling or for emptying
    • Adjustable probe signal delay: 1 to 10 sec
    • Adjustable pump start delay: 0 to 300 sec
    • Output: relay 8 Α (2 x NO+NC)
    • Indications: 1 LED (power supply ON) + 1 LED (relay ON)
    • Operation temperature: -20° to +60°C
    • Degree of protection: ΙΡ40
    • Dimensions: 3-DIN (53.5x98.3x58 mm)

    VH3/4 Carlo Gavazzi level hanging probes specification

    • Electrode material: stainless steel
    • Electrode cover: polycarbonate
    • Connection: VH3 = 6 m 1x1.5 mm2 UV resistance cable   VH4 =  double screw terminal
    • Operating temperature: 0°C to +80°C

    11SN1 Lovato Electric level hanging probes specification

    • Electrode material: stainless steel
    • Electrode cover: plastic (PPOX)
    • Connection: screw for cable 2.5 - 6 mm
    • Operating temperature: up to +60°C

     

    PHOTOS AND VIDEOS