DUB72, υπόταση DC, εκρηκτικό περιβάλλον
DC Double Under Voltage Level monitoring relay. Carlo Gavazzi

No need to put the DUB72 into a sealed enclosure to comply with hazardous location installation restrictions
Product Inquiry

Product Inquiry

DC Double Under Voltage Level monitoring relay. Carlo Gavazzi

    DETAILED DESCRIPTION

    DUB72

    A double under voltage relay for Class 1 Division 2 applications according to ANSI/ISA12.12.1 Norm for potentially explosive environments.
    The user can set two independent dials, one for each of the 2 thresholds, measuring the level of its power supply.  One of the thresholds, the one associated with output 1, can be used as a pre-alarm signal; the other is associated with a high-power 20A-rated relay which can be used to drive the load directly and features a low-profile DIN housing suitable for installation into electric distribution panels as well as industrial cabinets.
    Thanks to the high powered electromechanical 20 A relay, the second threshold / relay can be used to directly disconnect the battery or load.  The two relay outputs, can be associated to one of the set thresholds, can be used to drive different types of loads: the 3A can be used to send a signal to a PLC while the 20A, thanks to its high capacity, could directly drive the load.
    A green/red LED provides a visual indication of the alarm status. The number of RED blinks indicates the triggered alarm type.  The PCB tropicalisation increases operational reliability also in humid and dusty environments.
    As the DUB72 complies with the hazardous location installation norm, it is suitable for 24V-battery-voltage level monitoring, or any other DC voltage within the operating range of 16vdc to 26 v dc, in any environment including Class 1, Division 2 of potentially explosive environments. It is suitable for applications where it is necessary to monitor the battery charge level in Oil & Gas installations or agricultural industry.

    Specification

    • Power supply: 15VDC to 30VDC
    • Adjustable Threshold range: 16V to 26V
    • Reaction time: ≤ 250ms
    • Hysteresis: Adjustable 4 to 10%
    • Delay ON: None
    • Delay OFF: None
    • Outputs: 1 relay SPST 3 A and 1 relay SPST 20 A
    • Operating temperature: -25° C to 60° C